Abstract

Two unbonded posttensioned concrete masonry (PCM) cantilever walls were subjected to in-plane pseudostatic simulated seismic loading in the Civil Test Hall at the University of Auckland, New Zealand. The 67% scale wall units were designed to model a typical cantilever wall from a 4–5 story high office or apartment building. A detailed account of the wall construction, test setup, testing procedure, and test results are provided in this paper. The principal intent of these wall tests was to validate the use of PCM in a realistic structural configuration. The test units, incorporating reinforced concrete slabs at the intermediate floor levels, were subjected to a realistic moment gradient. Furthermore, the tests explored means of masonry confinement or strengthening that are expected to allow for reliable drift capacities beyond 1%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.