Abstract

The forces of nature represent the biggest challenge for engineering work in general and perhaps the most prominent of these forces. This generated by earthquake where engineering structure is exposed abnormal loads and stresses which places areal burden on structural engineers to find solutions and structural systems to increase resistance and effectiveness of engineering structure especially high rise concrete structures.

Highlights

  • IntroductionIncreasing the height of the building increases the effect of lateral loads on the building

  • Increasing the height of the building increases the effect of lateral loads on the building.The column-beam joints and the contact joint between column and the column in floor are the prominent joints exposed to seismic loads in structure.Strong column—weak beam joint is important concept in resisting seismic loads

  • This study is devoted to increase resist of structure by increase effectiveness and resistance of the contact joint between column and the column in floor. It is common in construction sites the pouring of concrete columns for each floor separately, the cohesion between columns one top of each for multiple stories structure by extension of steel bars mostly does not exceed 1.0 meter, so full height column of structure can be represented as a group of units of columns pouring one top of each, this may not represent a problem for low-rise structures but for sure represent a problem for high-rise structures especially when structure exposed to seismic loads as shown in (Figure 1 and Figure 2)

Read more

Summary

Introduction

Increasing the height of the building increases the effect of lateral loads on the building. This study is devoted to increase resist of structure by increase effectiveness and resistance of the contact joint between column and the column in floor (column-column joint) It is common in construction sites the pouring of concrete columns for each floor separately, the cohesion between columns one top of each for multiple stories structure by extension of steel bars mostly does not exceed 1.0 meter, so full height column of structure can be represented as a group of units of columns pouring one top of each, this may not represent a problem for low-rise structures but for sure represent a problem for high-rise structures especially when structure exposed to seismic loads as shown in (Figure 1 and Figure 2). Figure 2. photographs of damage caused by earthquakes [2]

Practical Application
Mathematical Achievement
Indications
Conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.