Abstract

Clay tile and wall assemblages were tested as compressive prisms with six types of tile units. Specimens were tested at eccentricity ratios of 0, 1/6, and 1/3. Wall column specimens were built in three heights for the 4-in. units (h/t=10, 20, 40) and in two heights for the 6-in. and 8-in. units (h/t=10, 20) and tested with eccentricity ratios of 0, 1/6, and 1/3. Since walls may span either vertically between floors or horizontally between walls and columns, the specimens, approximately 4 ft times 8 ft, of each unit type with the span perpendicular and with the span parallel to bed joints were tested. The shear capacity was determined from the diagonal tension test method of loading opposite corners of a square panel to cause tensile failure perpendicular to direction of load.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.