Abstract

AbstractThis paper, which focuses on a fatigue crack found in a main girder of a continuous steel girder bridge, assesses the remaining structural safety of the steel bridge with such a fatigue crack in order to judge whether or not urgent action such as closure to traffic or necessary temporary repairs and strengthening should be carried out. Therefore, an elastic‐plastic finite displacement analysis is carried out for the continuous three‐span non‐composite steel girder bridge with four main girders in which a fatigue crack about 1.1 m long in the web plate of the main girder was discovered during an inspection. From the analysis results it is found that the load redistribution function of the multiple main girder system was effective and the remaining load‐carrying capacity of such a bridge system is such that there will be no sudden collapse of the entire bridge.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.