Abstract

The present study focuses on the structural response of sandwich panels consisting of a commercial closed-cell foam core and thin aluminium sheet skins under static three-point bending loading. Panels of different thicknesses and span lengths were tested, and the influence of the foam density, core thickness and skin type on the response was revealed. The failure modes in bending were greatly dependent on the span length but independent on the foam thickness. For short spans, the deformed shape at failure was asymmetric, as opposed to a symmetric mode for long spans. The density and thickness of the foam core, the presence of reinforcing face sheets and the beam span determined the failure load and bending strength of the sandwich panels.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call