Abstract

The previous research introduced an innovative retrofitting technique for reinforced concrete beams using modularized steel plates. This technique enhances structural performance, offering a lightweight solution compared to conventional retrofitting methods using steel plates, and accommodates construction errors. However, a challenge arises due to the lack of integrity between unit steel plates. To address this, this study proposes a novel method of connecting each steel plate with bolts. The experimental results show that retrofitted beams achieved a maximum load of 311.9 kN, roughly 1.6 times that of non-retrofitted specimens, with the ductility of retrofitted beams being 3.3 times that of the non-retrofitted beams. Additionally, there was a 25% increase in load capacity for beams retrofitted with interconnected steel plates compared to those without connections between unit steel plates.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.