Abstract

The effectiveness of steel-reinforced grout (SRG) jacketing in improving the structural performance of deficient reinforced concrete (RC) columns is experimentally investigated in this study. Four full-scale cantilever columns were designed following the old construction practice (pre-1970s) in southern Europe. Due to lack of adequate seismic detailing, the columns were susceptible to buckling failure when subjected to combined axial loading and cyclic lateral displacement reversals, simulating seismic loading. Three alternative SRG jacketing configurations were applied differing in the number of layers and density of the Ultra High Tensile Strength Steel (UHTSS) textile. The test results demonstrated the efficiency of SRG jacketing to modify the response of the columns with poor detailing from brittle to ductile by substantially improving their overall structural performance. Finally, code formulations were used to assess the performance of the SRG jacketed columns.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.