Abstract

This paper presents the behaviour of a composite walling system consisting of two skins of profiled steel sheeting and an infill of concrete under in-plane cyclic shear loading. Double skin composite wall (DSCW) specimens with overall wall dimensions of 1626mm high by 720mm wide were tested. Steel sheet–concrete connections were provided by intermediate fasteners along the height and width of the wall to generate composite action. Two types of concrete namely self-consolidating concrete (SCC) and highly ductile engineered cementitious composite (ECC) as well as cold formed profiled steel sheet having same geometry but with two different yield strengths were incorporated to investigate their influence on the composite wall behaviour. The benefit of using mild over high strength steel was demonstrated through more ductile failure. Overall, ECC wall showed better performance showing lower stiffness degradation and higher displacement ductility as well as higher energy ductility (based on hysteretic loop) compared to its SCC counterpart.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.