Abstract

Two exterior CES beam-column joints with different failure mode, the beam yielding type and the joint shear failure type, were tested under lateral load reversals and variable axial load to investigate the structural performance. The test results indicated that the CES beam-column joins had the stable hysteresis behavior until large story drift angle of 1/20 radian. In addition, the use of the FRC facilitates to control the crack width of the joints. The development of stresses in the joint panel was clarified by the rosette analysis and non-linear FEM analysis. It is shown that the joint shear strength of exterior CES beam-column joints cloud be evaluated by the method based on AIJ design standard for SRC structures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.