Abstract
A static loading test was carried out on a two-bay two-story concrete encased steel (CES) frame in which the beams and columns consisted of only steel and fiber reinforced concrete (FRC). In this test, the structural behavior of the frame such as the failure modes, hysteresis characteristics and deformation capacity was examined. Although the frame designed to be a weak beam-strong column system with the flexural yielding at the both ends of beams and the bottom of the first story columns, the shear yielding in the joint panel of the interior beam-column joints also occurred. The results showed that the use of FRC in the CES frame controlled the damage of the concrete. In addition, the frame had stable hysteresis loops with almost no degradation in load carrying capacity until the average story drift angle of 0.05 rad. Static inelastic analysis with reversal loading was also conducted to simulate the story shear versus story drift response of the frame. It is shown that the analytical results agree well with the test results in this paper.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Structural and Construction Engineering (Transactions of AIJ)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.