Abstract

In this paper,waveform is used to excite Lamb waves in the test plates during experimental testing. The optimal excitation frequency will depend on the test configuration. In order to select an excitation frequency, dispersion curves are first created to show what frequency range is best suited for Lamb wave excitation. According to dispersion curves were created for the aluminum test plates and it was concluded that a frequency below 1 MHz will be used in order to only excite the fundamental and modes. Experiments are performed on the aluminum test plates described. Experimental testing is first performed on undamaged plates in order to determine the path-to-path and test-to-test variability in Lamb wave measurements in the absence of damage. The admittance data is analyzed in order to determine if any of the PZT transducers need to be replaced because of poor bonding or mechanical failure. The sensor diagnostic technique is applied to each plate and used to ensure proper consistency between PZT transducers

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.