Abstract
ITER ELM coils are important parts of in-vessel coils and they are mounted on the vacuum vessel and behind the blanket module. They consist of three sets of coils, referred to as the upper, mid, and lower coils. In order to verify the structural design feasibility and find the better structure for upper edge localized modes (ELM) coil, two different variants of coil support structures are studied under the electromagnetic load, thermal and other loads. Results show that besides the bracket of variant 2 does not meet the fatigue criteria, the conductor, jacket and bracket of the two structures can meet the static, fatigue and crack threshold criteria and both of them are valid and feasible. In addition, the better structure is chosen for upper ELM coil.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.