Abstract

In order to solve the problems of small pressure drop range and achieve lower response time and small power consumption of traditional control valves in automotive hydraulic lift, the magnetic circuit method was employed to design a new multi-ring and multi-disc magnetorheological valve based on magnetorheological fluid and its pressure drop mathematical model was established. Through the electromagnetic field simulation, the effect of current size, radial damping gap size, axial damping gap size and magnetic isolation thickness affect the performance of the multi-ring and multi-disc magnetorheological valve is studied. The pressure drop characteristics and response time of the multi-ring and multi-disc MR valve under different currents, different direction of loading current and different loads have been studied experimentally. The results show that the saturation pressure drop of the multi-ring and multi-disc MR valve is greater than 7 MPa, and the response time is 136 ms–178 ms, which proves the performance advantage of the multi-ring and multi-disc MR valve.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.