Abstract

This paper designs a miniaturized structure health detection system based on the electro-mechanical impedance (EMI) method. The system uses two orthogonal signals of the same frequency as the excitation source, which effectively solves the problem of determining the phase difference in phase detection. According to the characteristics of the piezoelectric sensor, the FPGA is used as the main control chip, the measurement frequency range is adjustable by the user, and transmitted through the wireless serial port. The admittance curve of the piezoelectric sensor is displayed on the host computer, and real-time calculation of the RMSD value and relative RMSD value of the admittance curve. Compared with the current impedance analyzer on the market, it has the characteristics of wide measurement frequency range, small size and low cost.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.