Abstract

This paper summarizes the results of a research program conducted to examine the structural behaviour of nine full scale ten ton Dolos armour units subjected to a well defined loading regime. Three unreinforced and six reinforced units were tested. The effects of three different types of reinforcement (rebars, hollow steel tubes, and prestressing bars) on the behaviour of the units was determined. Different design approaches for armour units are discussed and one possible new approach is presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.