Abstract

A Structural Insulated Panel (SIP) is a structural element of expanded polystyrene insulation (EPS) core sandwiched between two oriented-strand boards (OSB). This research proposes SIPs in low-rise residential construction (i.e. houses and low-residential building), replacing the traditional conventional joist floors and stud walls. This research investigates (i) developing expressions for flexural, compression, monotonic racking and cyclic lateral load capacities of SIPs as compared to the joist/stud wall construction. In this study, the proposed design of SIPs was based on (i) generally established theory for analysis, (ii) assessment of full-scale SIP panels by a loading tester, and (iii) computer modeling using the finite-element modeling. The research program included (i) testing SIP walls in axial compression and bending, (ii) racking and cyclic testing on SIP shear walls, (iii) development of finite-element computer models of the tested SIP panels and verifying those using experimental findings, (iv) correlation between experimental findings and design equations for strength and serviceability available in the literature and wood design Standards. Modification factors of these equations were developed to allow structural engineers to design SIP panels in residential construction more economically reliably. Experimental results showed that SIP panels are being “as good as” the conventional wood-framing of identical sizes, with respect to flexural, compressive, racking and cyclic loading. Also, results showed SIP walls have a greater ability to dissipate energy under racking and cyclic loading that the stud wall system. Therefore, SIP walls can be used so efficient in seismic zones. Based on cyclic lateral load test results, the values of ductility-related force modification factor (Rd) for stud wall, short SIP wall and long SIP wall were calculated as 8%, 22% and 14% lower than the NBCC required value for anchored wall (Rd = 3.0), respectively. In addition cyclic lateral load test results showed that the values of over-strength-related force modification factor (Ro) for stud wall, short SIP wall and long SIP wall were observed to be 17%, 20% and 14% higher than the recommended value of NBCC (Ro = 1.7) for anchored wall, respectively. So, it is concluded that the over-strength factor indicates a confident reserve of resistance in interconnected wall segments.

Highlights

  • General A Structural Insulated Panel (SIP) is a structural element of expanded polystyrene insulation (EPS) core sandwiched between two oriented-strand boards (OSB) or any other different material

  • The results of axial load and flexural tests performed in this study established a database that can be used further to develop design tables of structural insulated panel (SIP) floors and walls subjected to flexural, axial compressive loading or combined axial compressive loading and lateral bending moment resulting from wind loading

  • It has been noted that noise was heard when approaching failure load and the shear failure was abrupt causing a sudden drop in the applied jacking load

Read more

Summary

Introduction

Finite-element models were developed to predict the behavior of structural insulated panels under monotonic compressive loading. In this phase, the developed FE models were validated using the experimental data for SIP and stud wall panels under monotonic compressive loading.

Methods
Results
Conclusion