Abstract

The paper is a summary of the results of an experimental program conducted at the University of Texas to investigate the structural behavior of 7 shear wall assemblies used in manufactured housing. Variables studied include the size and location of the shear wall within the assembly, the number of glued sides of hardwood paneling, and the number of floor joists beneath the shear wall. It was found that walls located on the windward side of the assembly had higher ultimate strengths. In addition, measurements of slip between the shear wall and side walls indicate that there may be significant load transfer into the side wall. Also, the side walls, it was found, do not provide rigid vertical support to the joists beneath the shear wall, as currently assumed in design.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.