Various researches have been performed to find an effective confining method using FRP sheet in order to improve the structural capacity of reinforced concrete column. However, most of these researches were undertaken for the columns subjected to concentric compressive load or fully confined RC columns. To date, it remains hard to find studies on partially FRP-confined RC columns under eccentric load. In this manner, an experimental investigation was carried out to assess the performance of rectangular RC column with different patterns of CFRP-wrap subject to eccentric loads in this paper. The experiment consists of fourteen mid-scale rectangular RC columns of 200 mm × 200 mm × 800 mm, including five controlled columns and nine CFRP-strengthened ones. All CFRP-strengthened columns were reinforced with one layer of vertical CFRP sheet with the main fiber along the axial axis at four sides, then divided into three groups according to confinement purpose, namely unconfined, partially CFRP-confined, and fully CFRP-confined group. Two loading conditions, namely uniaxially and biaxially eccentric loads, are considered as one of the test parameters. From the test of uniaxial eccentric load, partial and full CFRP-wraps provided 19% and 33% increased load-carrying capacity at an eccentricity-to-column thickness ratio (e/h) of 0.125, respectively, compared to controlled columns, and 8% and 11% at e/h = 0.25, respectively. For the partially CFRP-confined columns subjected to biaxial eccentric load with e/h = 0.125 and 0.25, the load-carrying capacities were improved by 19% and 31%, respectively. This means that the partial confinement with CFRP effectively improves the load-carrying capacity at larger biaxial eccentric load. It was found that the load-carrying capacity could be properly predicted by using code equations of ACI 440.2R-17 and Fib Bulletin 14 Guideline for the full CFRP-confined or partially CFRP-confined columns under uniaxial load. For partially CFRP-confined columns under biaxial loading, however, the safety factors using the Fib calculation process were 20% to 31% lower than that of uniaxially loaded columns.

Highlights

  • Reinforced concrete (RC) columns are critical structural components in building

  • Results of this study showed that CFRP wrapping enhanced the load-carrying capacity and ductility of the columns under eccentric loading

  • linear variable differential transformers (LVDTs) were used for measuring the axial displacement while the remaining four

Read more

Summary

Introduction

Reinforced concrete (RC) columns are critical structural components in building. In order to increase the load-bearing capacity and ductility of the columns, the concrete core is confined by providing lateral pressure. For fully FRP-wrapped RC columns under eccentric compression, the load-carrying capacity and ductility of the columns have been improved significantly through several studies [1,2,3,4]. Results of this study showed that CFRP wrapping enhanced the load-carrying capacity (up to 18%) and ductility (up to 300%) of the columns under eccentric loading. The primary objectives are to (1) evaluate the CFRP strengthening efficiency of partially and fully confined RC columns under uniaxial and biaxial load; and (2) study the existing guidelines on CFRP confinement design to establish the safety factor of the predicted load-carrying capacity against the experimental results

Specimen Design
Material Properities
Strengthening with
Unidirectional carbon-fiber
Test Set Up and Installment of Equipment
SGs2 at each section as shown in Figure
Failure
Load-Displacement Relationship
10. Yielding
Load-Carrying Capacity and CFRP Strengthening Efficacy
11. Strength
15. Relationship
Design
Ag as follows:
Comparison of Experimental Results with Design Guideline Results
Conclusions