Abstract

This study assesses the state of the anatomical complex of the lens in MS using UBM. The study was carried out on clinical material previously used by us to analyze changes in the fibrous membrane of the eye in MS. At the first stage, the main (19 patients with MS, 38 eyes) and the control (24 patients with myopia, 48 eyes) groups were formed for comparative evaluation. The formed groups were standardized according to the age of the patients and the axial length of the eye. At the second stage, patients with MS were divided into subgroups depending on the absence or presence of biomicroscopic signs of ectopia lentis (22 and 16 eyes, respectively). For UBM, an ultrasound linear sensor with a scanning frequency of 50 MHz was used (Aviso device, Quantel Medical, France). Various biometric UBM indicators were determined: lens thickness, diameter of the lens, lens-axial length factor, iris-lens angle, iris-lens contact distance, posterior chamber depth, length of the fibers of ciliary zonule, thickness of the ciliary body, sclera-ciliary process angle. There are changes in the anatomical complex of the lens as a whole in MS (in the lens itself, the ciliary zonule, and the ciliary body), which are characterized by an increase in lens thickness and a decrease in the diameter of the lens, an increase in the length of the fibers of the ciliary zonule and a decrease in the thickness of the ciliary body. At the same time, the displacement of the lens detected by optical biomicroscopy (ectopia lentis) can be considered as an advanced stage of changes in the anatomical complex of the lens. UBM provides the possibility of full-fledged visualization of all components of the anatomical complex of the lens in terms of both diagnostics, and monitoring of changes in MS. The question of the advisability of including this method in the algorithm for diagnosing ocular manifestations in order to verify the MS remains open. Possible obstacles may be, on the one hand, related to the need for special and expensive equipment, and on the other hand, the absence of a generally accepted «normal» values of UBM indicators of the anatomical complex of the lens.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call