Abstract

The use of a new, modified Nd:YAG laser called the KTP/532 laser was evaluated within root canals to determine whether it would modify dentin permeability or alter the scanning electron microscopic appearance of canal dentin. Energies and exposure times were chosen which did not permit periodontal temperatures to increase above 5 degrees C (1 W x 1 s-5 W x 0.5 s). Half of the root canals were covered with smear layer and half were treated with EDTA/NaOCI to remove the smear layer. The results showed that this laser did not change the permeability of the smear layer-covered dentin, although scanning electron microscopic examination revealed modifications to the surface of smear layer. Lasing of etched dentin produced modest increases in root permeability which were associated with enlargement and cracking of tubule orifices.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.