Abstract
The structural integrity of the ITER thermal shield (TS) has been verified by structural analysis. In this paper, the analysis process methodology and demonstration of the structural integrity for the TS are described. The analysis is performed for the TS global models and detailed models, such as supports and joints. TS joints in the shell model are modeled using orthotropic material properties. To verify the structural reliability for the TS, plastic collapse, buckling, ratcheting, and fatigue are assessed in accordance with ASME Section VIII, Div. 2.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.