Abstract

The stroboscopic visibility measure (SVM) is a method used to quantify the stroboscopic effect visibility in general illumination application. SVM has been defined previously based on a limited number of frequencies and participants. To validate and extend SVM, five perception experiments are presented, measuring the visibility threshold of light waveforms modulated at several frequencies, conducted in two different labs. A power function is fitted through the aggregated results to develop a stroboscopic effect contrast threshold function for a "standard observer," which can be used to normalize SVM. An additional experiment shows the dependency on illumination level, extending the validity of SVM to other applications.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call