A compact string-guided transport (SGT) system for samples irradiated by intense 60Co γ-rays has been developed for the study of resonance photoactivation of short-lived isomers. The path length from the irradiation port to the measuring port was 12.5 m and the transport time was within 3–4 s for samples up to 90 g. Results of half-life measurements of 79mBr and 77mSe were 5.06±0.44 and 17.4±0.8 s, respectively. The integral cross-sections of 79mBr and 77mSe were determined as 169±27 and 937±99 μb keV, respectively, on the basis of the 115mIn cross section.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.