Abstract
Mechanically activated ion channels (MACs) in rat ventricular myocytes were activated by stretching membrane patches attached to microelectrodes. Charge injection from MACs, consisting mainly of inward K+, was sometimes of sufficient magnitude (0.2 pC) during brief (50 ms) periods, to trigger action currents. Action currents were shown to be extracellular records of action potentials. These results demonstrate the activation of myocytes by injection of approximately 4 pA from a few MACs in a membrane patch.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.