Abstract

Available test results and stress–strain models for poorly confined high-strength columns, more specifically for columns with a tie volumetric ratio smaller than 2·0%, are scarce. This paper presents test results loaded in the axial direction for square reinforced concrete (RC) columns confined by various volumetric ratio lateral ties including low volumetric ratio. Test variables include concrete compressive strength, tie yield strength, tie arrangement type and tie volumetric ratio. Local strains are measured using strain gauges bonded to an acryl rod. For square RC columns confined by lateral ties, the confinement effect was improved by changing tie arrangement type from type A to type B. A method to compute the stress in lateral ties at the concrete peak strength is proposed, as well as a new stress–strain model for the confined concrete. The model shows good agreement with stress–strain relationships established experimentally over a wide range of confinement parameters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.