Abstract

A novel stress-relaxation structure with a ring-shaped beam for ensuring stability in a piezoresistive three-axis accelerometer assembled using wafer-level encapsulation and resin-mold packaging is proposed and evaluated in this paper. The reduction of the unstable increase in sensitivity due to buckling against three stress sources, i.e., the thermal stress in device fabrication, wafer bonding, and resin molding, was evaluated by both computer simulation and experiments on test samples. The measured increase in sensitivity due to stress during wafer bonding and resin molding was kept at 1.26 times using the ring-shaped beam, compared with 7.64 times when using a conventional straight beam. In addition, the standard deviation in the sensitivity of resin-molded samples was kept at 0.04 mV/G using the ring-shaped beam, compared with 2.19 mV/G using the straight beam. The sensitivity variation against the temperature change was also kept small and linear; thus, the effect of the ring-shaped beam was confirmed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.