Abstract

Goal of this research was to find out if reorientation can influence cladding failure and determine conditions and possible mechanism of failure. Reorientation tests were done on zircaloy nuclear fuel cladding specimens. Specimens were made having two triangular notches along specimen axis which are similar to the surface flaw that can form during operation. Loading was applied using PLT loading fixture to give stress proportional to a distance from the specimen front. When loaded, specimen was cooled from 340 to 40 °C at a cooling rate 0.25 °/min., total duration of test was 20h. After testing, specimen was examined layer by layer metallographically to determine hydride reorientation under certain stress conditions. In case of a surface flaw reorientation of hydrides takes place perpendicular to the stress direction. It was found that hydride reorientation occurs at a stress range 77 – 89 MPa, for initiation of DHC process larger stress is required than for hydride reorientation. DOI: http://dx.doi.org/10.5755/j01.ms.20.4.5477

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call