Abstract

Zirconium has been utilized in reprocessing plant because of its superior corrosion resistance. But Stress corrosion cracking (SCC) susceptibility had been reported in some conditions. In order to clarify the SCC occurrence criteria of Zr in boiling nitric acid solution, constant load tests at potentiostatic condition were conducted. From the results, SCC of Zr in nitric acid solution occurred only at transpassive region. And it is attributes to tarnish rupture model. From the observation of intermediate samples, many cracks initiate under oxide film and then the maximum crack grown to rupture. If the reprocessing plant operates in the potential of passivity region, SCC of Zr will not occur.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.