Abstract

This paper describes a stress corrosion cracking (SCC) failure case of super 13Cr tubing serviced for six years in a high-pressure, high-temperature (HPHT) gas well. The failure causes and processes were studied by various characterizations and SCC simulation testing. The failure mode of super 13Cr tubing is brittle transgranular fracture, and the dominating role in SCC failure is the synergistic action of KH2PO4 phosphate packer fluid and CO2, leading to corrosion damaged zone, which is a selective corrosion along the martensitic multiscale boundaries. Under tensile stress, cracks developed at the corroded martensitic multiscale boundaries and propagated due to the low structural strength of the corrosion-damaged zone. Due to its compatibility with 13Cr tubing, formate is recommended as an alternate packer fluid for high-pressure, high-temperature (HPHT) gas wells.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.