Abstract
In this work, a non-steady electrochemical model for assessing stress corrosion cracking (SCC) of 2205 duplex stainless steel (DSS) under applied polarization potentials was proposed, and the SCC mechanism was revealed. With the negative shift of potentials, hydrogen enhances SCC susceptibility by deteriorating passive film, inhibiting repassivation and causing serious damage. In particular, at −850 mV (vs. SCE), the synergetic effect of anodic dissolution (AD) and hydrogen embrittlement (HE) causes severe pitting and SCC. The negative shift of applied potentials changes the preferential pit/SCC initiation site due to high hydrogen concentration in austenite.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.