Abstract
This study examined the cause of the mechanical fracture (cracking) of dielectrics observed after chemical mechanical polishing (CMP) in the damascene interconnect process for W/oxide structures through the stress analysis of dielectrics with the finite element method (FEM). The analysis, performed considering polishing pressure during CMP and residual film stress, revealed that the stress in dielectrics generated by polishing pressure during CMP was approximately 2% of that generated through W film removal. This result suggests a high likelihood that the cracking of dielectrics observed after CMP is caused by the release of residual stress in W film through CMP. To prevent the mechanical fracture of dielectrics, it is thus important to reduce defects in the deposition of dielectrics and to decrease residual film stress.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.