Abstract This study is carried out to investigate the effectiveness of using externally applied epoxy mortar on joints of masonry wall panels to enhance their load carrying capacity under axial compressive and lateral loads. A total of six 113 mm thick masonry wall panels of size 1200 x 1200 mm were constructed for this study. Four out of six walls were strengthened using locally available CHEMDUR-31 epoxy mortar on joints. The remaining two walls were tested as control specimens. The control and strengthened wall panels were tested under axial compression and lateral loads. In axial compression test, out of plane central deflection and vertical strain at the center of wall panel were recorded while in lateral load test, in-plane lateral displacement of wall and horizontal strain at the center were recorded at each load increment. Failure pattern of each wall panel is also studied to notice its structural behavior. The results of this experimental study showed an increase of 45% and 60% in load carrying capacity under axial compression and lateral bending, respectively by the use of strengthening technique employed in this study.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.