Abstract
The strengthening of existing reinforced concrete structures (RC) with carbon reinforced concrete (CRC) has a high potential to save resources and to increase the lifespan of the whole strengthened structure immensely. However, when strengthening structures with CRC, in some cases, failure due to concrete cover separation is detected, leading to the fact that the potential of the carbon reinforcement cannot be exploited. The prediction and prevention of this type of failure is the subject of current research. In this paper, a strut-and-tie-model is presented for calculating a critical tensile force leading to failure due to concrete cover separation. Additionally, possible methods to avoid that kind of failure are suggested. One of these is doweling the ends of the strengthening layer. This paper presents the first experiments to test this method, which show that doweling the strengthening layer leads to much higher failure loads compared to a structure without doweling. However, further investigations have to be examined to verify these first results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.