Abstract
Thirty masonry walls strengthened using three different fiber-reinforced polymer (FRP) systems, with three anchorage methods, were fabricated and tested under a concentrated load over a 100 mm square area or a patch load over a 500 mm square area. The test results indicated a significant increase in the out-of-plane wall strength over the unstrengthened wall. While failure occurred in the unstrengthened wall by bending, four different modes of failure, that is, punching shear through the bricks, debonding of FRP reinforcement from the masonry substrate, crushing of brick in compression, and tensile rupture of the FRP reinforcement, were observed in the strengthened walls, depending on the types and configurations of FRP and anchorage systems. With appropriate surface preparation and anchorage systems, premature failure due to FRP debonding is prevented. Based on the principles of strain compatibility and force equilibrium, simple analytical models are presented to predict the ultimate load-carrying capaci...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.