Abstract

The purpose of this study was to investigate the effectiveness of different strengthening schemes in strengthening heat damaged reinforced concrete short columns. A series of 63 heat damaged specimens were tested under concentric compression after jacketing externally with High Strength Fiber Reinforced Concrete (HSFRC), Ferrocement (FC) and Glass Fiber Reinforced Polymer (GFRP) jackets. The specimens were subjected to various heating and cooling regimes. The overall response of strengthened specimens was investigated with reference to un-strengthened specimens in terms of axial compressive strength, ductility, lateral stress-strain, and axial stress-strain behaviour. It was observed that while the GFRP jacketing is quite effective in improving compressive strength and energy dissipation, it is not capable of improving stiffness. On the contrary FC and HSFRC jacketing were mainly effective in improving stiffness property. Overall GFRP jacketing was found to be the most effective method of strengthening fire or heat damaged concrete columns.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.