Abstract

This paper presented a strengthening technique for enhancement reinforced concrete (RC) slab-column connection behavior using steel plates and steel stiffeners. A bi-axial load was applied with an eccentricity of 150 mm in both x and z directions. Four specimens with dimensions of 1,600 × 1,600 × 100 mm were tested in this research. The steel plate dimensions were chosen to be 600 × 600 and 800 × 800 mm with 6 mm thickness. The steel stiffeners are used to support and enhance the steel plate that it is extended from column to the slab-column connection with different dimension. The results showed an improvement in the stiffness of slab and increasing in the ultimate capacity. Also, when the steel plates dimensions increased, the ultimate capacity and stiffness increased.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.