Abstract
A 90,000 square meter, three-story, precast concrete parking garage in Pittsburgh, PA was strengthened in order to address concerns regarding distress in the double tee beams supporting each elevated floor. Initially, the distress was manifest in inclined cracks forming at the reentrant corner of the dapped ends. During an independent load test of sample tees, additional cracks at approximately 1.5 m from the dapped end formed and became so severe that, at roughly 75% of the design load, the tees were deemed to have failed. This failure condition resulted in an effort to strengthen the ends of the tees in the garage for shear and flexure. In assessing various strengthening alternatives, externally bonded carbon fiber reinforced polymer (FRP) reinforcement was determined to be the most cost effective, the least disruptive to the operation of the parking garage, and virtually unnoticeable once the installation was complete. A load test of several tees after the installation of the FRP reinforcement demonstrated that the retrofitted tees could support loads over 100% of the design load. This paper presents the details of the design, specification, installation, and testing of the FRP strengthening system for this large retrofit project.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.