Abstract
Three specimens with ribbed stainless steel rebar and one specimen with ribbed ordinary steel rebar are tested concerning the strength degradation and energy dissipation of stainless steel reinforced concrete columns. The tests results indicate that the damage of the specimens exhibit ductile failure characteristics, and the reinforced concrete columns with stainless steel rebar damage to a lesser extent, appear good ductility and energy dissipation. The strength degradation of stainless steel reinforced column with high axial compression ratio is quite obvious, and with the increasing of the stirrup ratio of column with stainless steel rebar, the strength of column is enhanced.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.