Abstract

The aim of the study was to analyse the strength of a prosthetic bridge with variable geometry in the connectors between the span and the retention elements on the pillar teeth crowns. Research was carried using the Finite Elements Method (FEM) on a model of the bridge in the anterior teeth arch in the field 21-22-23, obtained using a contact scanner and computer aided design (CAD) system, with four different cross-sectional areas of the connectors: 4.0, 5.0, 5.5, and 6.0 mm2. For that purpose, the impact of the properties of selected metal alloys on the deflection of the prosthesis was analysed. On the basis of the analyses, it was found that when the loading force acted obliquely, the stress was 19% higher compared to the stress with a loading vertical force. In the case of connectors with the smallest cross-sectional area, the stress exceeded permissible value (with safety factor n = 2) for one of the alloys. Deflection of the bridges tested changed depending on the connector cross-section and the elastic modulus of the selected material.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.