Abstract

ABSTRACT: Ninety‐one sediment oxygen demand (SOD) samples from six designated sites along the stretch of Lower Rapid Creek, South Dakota, were conducted using an in‐situ SOD chamber. Inside the chamber, readings of dissolved oxygen (DO), water temperature, pH, and specific conductance were recorded every minute for more than one hour using the Datasonde 3 Hydrolab. Initial readings of such parameters were recorded for the overlaying water before the deployment of the SOD chamber. Characteristics of the stream conditions, air temperature, barometric pressure, average flow velocity of the stream, depth of the stream, and the flow velocity by the chamber were recorded. Single and multiple linear regression analyses on all parameters indicated that the velocity of the stream is the least critical parameter for SOD in shallow streams.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.