Abstract

Streaked x-ray radiography images of annular patterns in an evolving tantalum oxide foam under the influence of a driven, subsonic radiation wave were obtained on the National Ignition Facility. This is the first successful radiography measurement of the evolution of well-defined foam features under a driven, subsonic wave in the diffusive regime. A continuous record of the evolution was recorded on an x-ray streak camera, using a slot-apertured point-projection backlighter with an 8 ns nickel source (7.9 keV). Radiography images were obtained for four different annular patterns, which were corrected using a source-dependent flat-field image. The evolution of the foam features was well-modeled using the 3D KULL radiation hydrodynamics code. This experimental and modeling platform can be modified for scaled high-energy-density laboratory astrophysics experiments.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call