Abstract

Purpose: We propose the measurement method of tumor movement for respiratory gated therapy in lung cancer patient for stereotactic radiosurgery, contouring method of tumor for radiation treatment planning using measured tumor movement. And through phantom study, we ascertain that the tumor movement is properly reflected in determination of PTV, and the tumor is properly and safely treated in full respiration phases and respiratory gated therapy. Materials and Methods: Lung cancer phantom and 1-dimensional moving phantom were made to evaluate respiratory gated radiation therapy for lung SRS. 4D CT scan was performed using these phantoms and 10 sets of CT images and post-processed MIP (Maximum Intensity Projection) images were used to measure the tumor movement. The measured tumor movement in 4D CT images and MIP images were compared. Also, during radiation exposure in full respiration phases and respiratory gated phases, tumor movement included in radiation exposure was measured using EPID image and compared with measured data in 4D CT images and MIP images. Results: The tumor movement measured in full respiration phases was 28.8mm and 29.1 mm in 4D CT images and MIP images respectively, and in respiratory gated phases, 30∼70% phases, was 12 mm and 12.2 mm respectively. The tumor contoured in each phase images and MIP images was well agreed in full respiration phases and respiratory gated phases. The tumor movement included in radiation exposure was 29.3 mm and 8.4 mm in full respiration phases and respiratory gated phases respectively. Conclusion: The tumor movement measured in 4D CT images and MIP images was well agreed, so we propose to use of MIP image for contouring of tumor in full respiration phases and respiratory gated phases. In full respiration radiation treatment and respiratory gated radiation therapy, the tumor movement included in radiation exposure was well agreed with measured tumor movement in 4D CT images or MIP images, so we ascertain though this phantom study we can exactly treat the tumor including tumor movement. In respiratory gated radiation therapy, the tumor movement included in radiation exposure was about 30% smaller than measured tumor movement in 4D CT images or MIP images, so we ascertain that we can safely treat the tumor including tumor movement in current provided technique. (J Lung Cancer 2007;6(1):29 �� 34)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.