Abstract

A calibration procedure is proposed for ITER Radial Neutron Camera that relies on embedded sources, reference ITER pulses and cross-calibration with ITER fission chambers and activation system coupled to Monte Carlo simulations of radiation transport. The proposed procedure would allow to measure the neutron emissivity profile and of the fusion power with 10 % accuracy and precision, a time resolution of 10 ms and a spatial resolution of a/10 for ITER entire life-time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.