Abstract

This paper presents a discussion of sampling and analytical techniques for continuous monitoring of hydrogen chloride (HCl) emissions from incineration sources. The discussion focuses on commercially available systems for sample conditioning and measurement. Six HCl continuous emission monitors were evaluated at a municipal facility for solid waste incineration. Field test results indicate that several techniques for continuous monitoring of HCl concentrations are available. Most of the analyzers tested, regardless of the detection or calibration techniques, indicated the same trend in the effluent HCl concentrations and produced data that were in good agreement with wet chemistry results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.