Abstract

Arrays of identical polyimide cantilever beams have been fabricated with nickel-chrome strain gauges covering an increasing portion of the beam. In contrast to accepted beam models, testing showed that gauge factor increased 136% for polyimide beams as the strain gauge extended over a larger length of the beam. This effect is due to the high modulus of the thin film strain gauges relative to the polymer beams, a hypothesis supported by duplicate experiments with silicon nitride beams that showed a 65% reduction in gauge factor. Comparison with an analytical model and finite element analysis is also made, giving good agreement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.