Abstract
A customized digital image correlation (DIC) system was implemented to monitor the strain produced in a cold-rolled AL-6XN stainless steel plate, 3.0 mm thick, subjected to quasi-static and cyclic loading tests. A comparison of the DIC strain measurements was made against those provided by conventional extensometers. Furthermore, the DIC system was used to monitor the fatigue crack initiation in low-cycle fatigue tests. The true stress-strain behavior for the AL-6XN material was properly captured by the DIC measurements. For low-cycle fatigue tests (strain control), the strain mapping generated by DIC allowed for identifying zones with higher strain than the nominal strain amplitude applied (εa) since the first stages of the fatigue life (FL). These zones become potential fatigue crack initiation sites.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.