Abstract

A study of mass measurement using strain gauge 120 which was placed in the corner of the brass cantilever has been done. This study essentially utilizes deflection phenomena on the surface. This phenomenon occurs due to the mass placed on one end of the brass cantilever. The Mass was calibrated with standard mass gauge using OHAUS PA214 Pioneer<sup>TM</sup> analytical balance. It was done a variation of mass-reduction and addition at the end of the brass cantilever with a multiple of 0.1 gram over a span interval of 1.1-7.5 grams. It obtained hysteresis curve plot for the changing strain gauge resistance (ΔR) versus mass variations on which the system has the maximum load range (7,1-7,5 gram). Moreover, The test of the system for the mass variations in the output voltage of the IC AD521JD differential amplifier was approximated as a quadratic function which was expressed in the system characteristic equation m = 2,4×V<sup>2</sup> - 0,8533×V + 1,1449, with m (gram) and V (Volt). The characteristic equation is used in the ADC conversion of the microcontroller. The measured mass value was displayed on 2 × 16 LCDs in grams.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.