Abstract

The following paper explores the development the bulge test technique combined with the micro-Raman analysis and a refined load-deflection model for high quality 3C-SiC squared-membranes. By the minimization of the total elastic energy, starting from the isotropic relation between the stress tensor and the strain tensor, it is possible to calculate the relationship between the maximum deflection and the applied pressure, in both regime of small and large deflection. From the measured breaking pressure through the refined model it is possible to evaluate the breaking strain of the membrane. Furthermore, the relationship between the measured shift of Raman Transverse Optical (TO) phonon modes and the total residual strain (Δa/a) within the epitaxial 3C-SiC layer was found.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.