Abstract

In the context of the continued increased global uptake of fingerprinting procedures to explore fluvial sediment sources, far less attention has been paid to dust source tracing and especially using different particle size fractions and low-cost tracers such as colour and magnetic susceptibility. The objective of this study, therefore, was to apportion local dust storm source contributions for the < 63-μm and 63-125-μm fractions of dust samples in a case study in central Iran. Colour and magnetic susceptibility properties were measured on 62 source samples and six dust storm samples. Statistical methods were used to select four different composite fingerprints for discriminating the dust sediment sources. These statistical approaches comprised (1) the Kruskal-Wallis H test (KW-H), (2) a combination of KW-H and discriminant function analysis (DFA), (3) a combination of KW-H and principal components and classification analysis (PCCA), and (4) a combination of KW-H and a general classification and regression tree model (GCRTM). Local dust source contributions were ascribed using a Bayesian un-mixing model using the final composite fingerprints. For both the < 63- and 63-125-μm fractions, the different composite signatures consistently suggested that alluvial fan material was the dominant source of the dust samples. The root mean square differences between the apportionment results using the different fingerprints ranged from 0.5 to 1.6% for the < 63-μm fraction and from 1.8 to 5.8% for the 63-125-μm fraction. The Wald-Wolfowitz runs test was used to compare the posterior distributions of the predicted source proportions created using the alternative final composite fingerprints and the results indicated that most of the pairwise comparisons were significantly different (p ≤ 0.05). For the < 63-μm fraction, the RMSE and MAE estimates of divergence between the modelled and known virtual source mixtures using the different final composite signatures ranged between 1.5 and 23.4% (with a corresponding mean value of 9.4%). The equivalent estimates for the 63-125-μm fraction were 1.2-20.1% (8.3%). The findings clearly demonstrate that colour and magnetic susceptibility tracers offer low-cost options for apportioning dust sources.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.