Abstract

Two new stopping criteria designed to terminate automatically inactive cycle runs in Monte Carlo (MC) neutronics eigenvalue calculations are derived in terms of the covariance matrix of stochastic error components inherent in the stationary fission source distribution (FSD) from each stationary MC cycle run. A practical way to determine the covariance matrix using nonstationary FSD in the course of inactive cycle MC runs is presented. The effectiveness of the new stopping criteria including the way to calculate the covariance matrix is examined through continuous energy MC neutronics calculations for ten pressurized water reactor test problems with varying dominance ratios. It is shown that the empiricism-free new stopping criteria stop inactive cycle MC runs effectively and that FSDs from the termination of inactive MC runs are stationary consistent with the available posterior source convergence diagnosis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.